title: Ekahau Site Survey - Post Survey, Grand Falls, NB, Canada
description: A predictive wireless design survey using 10 Cisco C9120AXI access points mounted on the drop ceiling in office area and on the metal bar in the warehouse.
---

[Blog | US & Canada Wireless Site Services and more](https://www.usorion.com/blog)

# [Ekahau Site Survey - Post Survey, Grand Falls, NB, Canada](https://www.usorion.com/blog/ekahau-site-survey-post-survey-grand-falls-nb-canada)

 Written by [Orion US](https://www.usorion.com/blog/author/orion-us) | Aug 20, 2024 12:04:12 AM

We developed a WLAN system for a distinguished firm located in Grand Fall, New Brunswick, tailored for their office space. The office measured 1301 square feet with ceilings at a height of 10 feet. The project included a preliminary site survey and design, followed by a post-validation site survey, incorporating ping tests across the entire location. The details of the surveys are below.

Site type: Office

Area: 1301 sq ft

**Height:** 10 ft

**Survey type:** Pre-Survey using APoS design and Validation Post Survey of wireless infrastructure

**Coverage:** 2.4 GHz and 5GHz

**AP used for APoS:**Cisco 3802i

**Antenna:**NA

 

|   | **5 GHz** | **2.4 GHz** |
| --- | --- | --- |
| **Signal Strength** | -65 dBm | -65 dBm |
| **Secondary signal strength** |  -68 dBm |  -68 dBm |
| **Signal-to-noise ratio** |  25 dB |  25 dB |
| **Data rate** | 12 Mbps |  12 Mbps |

### 5 GHz Signal Strength

                                      *  5 GHz Signal Strength*

### 2.4 GHz SNR:

                                                                                                                      *2.4 GHz SNR*

Some photos from the site below:

 

 

 

 

      

Please [get in touch](https://www.usorion.com/contact-us-orion-us) with the experts at Orion US today.

<https://www.usorion.com/contact-us-orion-us>

Image Source: [Canva](https://www.canva.com/photos/MADI_h087RQ-women-working-with-cables-in-data-center/)

[View full post](https://www.usorion.com/blog/ekahau-site-survey-post-survey-grand-falls-nb-canada)

```json
{
  "@context" : "http://schema.org",
  "@type" : "BlogPosting",
  "author" : {
    "@type" : "Person",
    "name" : "Orion US"
  },
  "dateModified" : "2024-09-04T22:21:32.037Z",
  "datePublished" : "2024-08-20T00:04:12Z",
  "headline" : "Ekahau Site Survey - Post Survey, Grand Falls, NB, Canada",
  "image" : {
    "@type" : "ImageObject",
    "height" : 451,
    "url" : "https://23748016.fs1.hubspotusercontent-na1.net/hubfs/23748016/Imported%20sitepage%20images/rs=w1280-Jun-25-2024-05-35-27-9373-PM.jpg",
    "width" : 553
  },
  "mainEntityOfPage" : "https://www.usorion.com/blog/ekahau-site-survey-post-survey-grand-falls-nb-canada",
  "publisher" : {
    "@type" : "Organization",
    "logo" : {
      "@type" : "ImageObject",
      "height" : 60,
      "url" : "/hs/hsstatic/content_shared_assets/static-1.4092/img/default-amp-logo.png",
      "width" : 60
    },
    "name" : "Blog"
  }
}
```